Sets whether to enable the maximum pulse count for pulse measurements.You must configure this method when you set the SegmentedAcquisitionEnabled method to False.

Syntax

Namespace: NationalInstruments.RFmx.PulseMX

public int SetMaximumPulseCountEnabled(string selectorString, RFmxPulseMXMaximumPulseCountEnabled value)

Remarks

This method sets the value of MaximumPulseCountEnabled attribute.The default value is False.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

valueRFmxPulseMXMaximumPulseCountEnabled

Specifies whether to enable the maximum pulse count for pulse measurements.You must configure this method when you set the SegmentedAcquisitionEnabled method to False.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.