Resets an attribute that you specify in the attributeID parameter to default values.

Syntax

int32 __stdcall RFmxPulse_ResetAttribute(niRFmxInstrHandle instrumentHandle, char selectorString[], int32 attributeId)

Parameters

NameDirectionTypeDescription
instrumentHandle[in]niRFmxInstrHandle

Identifies the RFmx session. You can obtain this parameter from the RFmxPulse_Initialize function.

selectorString[in]char

Specifies the selector string for the attribute being reset. Refer to the Selector String (C or LabWindows/CVI) topic for more information about configuring the selector string.

attributeId[in]int32

Pass the ID of an attribute.

Returns

Returns the status code of this operation. The status code either indicates success or describes an error or warning condition. Examine the status code from each call to an RFmx function to determine if an error has occurred.

To obtain a text description of the status code and additional information about the error condition, call the RFmxPulse_GetError function.

The general meaning of the status code is as follows:

Value

Meaning

0

Success

Positive Values

Warnings

Negative Values

Errors