Externalattntable
- Updated2025-10-13
- 2 minute(s) read
Groups
Group members
| Name | Description |
|---|---|
| RFmxInstr_CfgExternalAttenuationTable | Stores the external attenuation table in the calibration plane specified by the Selector String parameter. On a MIMO session, the external attenuation table is stored for each MIMO port in the specified calibration plane. |
| RFmxInstr_CfgSParameterExternalAttenuationTable | Stores the S-parameter table in the calibration plane specified by the Selector String parameter. On a MIMO session, the S-parameter table is stored for each MIMO port in the specified calibration plane. |
| RFmxInstr_CfgSParameterExternalAttenuationTableSplit | Stores the S-parameter table in the calibration plane specified by the Selector String parameter. On a MIMO session, the S-parameter table is stored for each MIMO port in the specified calibration plane. |
| RFmxInstr_CfgSParameterExternalAttenuationType | Configures the type of S-parameter to apply to measurements on the specified port for a Calplane. You can use the Selector String input to specify the name of the Calplane and port to configure for S-parameter. |
| RFmxInstr_DeleteAllExternalAttenuationTables | Deletes all the external attenuation tables in the calibration plane specified by the Selector String parameter. On a MIMO session, this function deletes all the external attenuation tables for the specified MIMO port. |
| RFmxInstr_DeleteExternalAttenuationTable | Deletes the external attenuation table set by the Table Name parameter in the calibration plane specified by the Selector String parameter. On a MIMO session, this function deletes the external attenuation table for the specified MIMO port. |
| RFmxInstr_DisableCalibrationPlane | Disables the calibration plane specified by the Selector String parameter for amplitude correction. |
| RFmxInstr_EnableCalibrationPlane | Enables the calibration plane specified by the Selector String parameter for amplitude correction. |
| RFmxInstr_GetExternalAttenuationTableActualValue | Returns the external attenuation table actual value that is applied to the measurements for a specified signal and calibration plane. |
| RFmxInstr_GetSParameterExternalAttenuationType | Returns the type of S-parameter that is applied to the measurements on the specified port on a Calplane. You can use the Selector String input to specify the name of the Calplane and port to configure for S-parameter. |
| RFmxInstr_LoadSParameterExternalAttenuationTableFromS2PFile | Stores the S-parameter table from the S2P file in the calibration plane specified by the Selector String parameter. S-parameter tables are used for fixture de-embedding. On a MIMO session, the S-parameter table is stored for each MIMO port in the specified calibration plane. |
| RFmxInstr_SelectActiveExternalAttenuationTable | Activates the external attenuation table set by the Table Name parameter in the calibration plane specified by the Selector String parameter. On a MIMO session, this function selects the active external attenuation table for the specified MIMO port. The specified table will be used for amplitude correction during measurement. |
Attachments