Groups

Group members

NameDescription
RFmxInstr_CfgExternalAttenuationTable

Stores the external attenuation table in the calibration plane specified by the Selector String parameter. On a MIMO session, the external attenuation table is stored for each MIMO port in the specified calibration plane.

RFmxInstr_CfgSParameterExternalAttenuationTable

Stores the S-parameter table in the calibration plane specified by the Selector String parameter. On a MIMO session, the S-parameter table is stored for each MIMO port in the specified calibration plane.

RFmxInstr_CfgSParameterExternalAttenuationTableSplit

Stores the S-parameter table in the calibration plane specified by the Selector String parameter. On a MIMO session, the S-parameter table is stored for each MIMO port in the specified calibration plane.

RFmxInstr_CfgSParameterExternalAttenuationType

Configures the type of S-parameter to apply to measurements on the specified port for a Calplane. You can use the Selector String input to specify the name of the Calplane and port to configure for S-parameter.

RFmxInstr_DeleteAllExternalAttenuationTables

Deletes all the external attenuation tables in the calibration plane specified by the Selector String parameter. On a MIMO session, this function deletes all the external attenuation tables for the specified MIMO port.

RFmxInstr_DeleteExternalAttenuationTable

Deletes the external attenuation table set by the Table Name parameter in the calibration plane specified by the Selector String parameter. On a MIMO session, this function deletes the external attenuation table for the specified MIMO port.

RFmxInstr_DisableCalibrationPlane

Disables the calibration plane specified by the Selector String parameter for amplitude correction.

RFmxInstr_EnableCalibrationPlane

Enables the calibration plane specified by the Selector String parameter for amplitude correction.

RFmxInstr_GetExternalAttenuationTableActualValue

Returns the external attenuation table actual value that is applied to the measurements for a specified signal and calibration plane.

RFmxInstr_GetSParameterExternalAttenuationType

Returns the type of S-parameter that is applied to the measurements on the specified port on a Calplane. You can use the Selector String input to specify the name of the Calplane and port to configure for S-parameter.

RFmxInstr_LoadSParameterExternalAttenuationTableFromS2PFile

Stores the S-parameter table from the S2P file in the calibration plane specified by the Selector String parameter. S-parameter tables are used for fixture de-embedding. On a MIMO session, the S-parameter table is stored for each MIMO port in the specified calibration plane.

RFmxInstr_SelectActiveExternalAttenuationTable

Activates the external attenuation table set by the Table Name parameter in the calibration plane specified by the Selector String parameter. On a MIMO session, this function selects the active external attenuation table for the specified MIMO port. The specified table will be used for amplitude correction during measurement.

Attachments