FetchMaximumHalfSlotPhaseDiscontinuity(string, double, out double)
- Updated2025-04-08
- 1 minute(s) read
Fetches the maximum phase discontinuity observed at half-slot boundaries in the measurement interval.
Syntax
Namespace: NationalInstruments.RFmx.EvdoMX
public int FetchMaximumHalfSlotPhaseDiscontinuity(string selectorString, double timeout, out double maximumHalfSlotPhaseDiscontinuity)
Parameters
Name | Type | Description |
---|---|---|
selectorString | string | Pass an empty string. The signal name that is passed when creating the signal configuration is used. |
timeout | double | Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete. |
maximumHalfSlotPhaseDiscontinuity | out double | Upon return, contains the maximum slot phase discontinuity value observed in the measurement interval. This value is expressed in degrees. |
Returns