Sets the Walsh code length of the channel, subject to channel-specific analysis.

Syntax

Namespace: NationalInstruments.RFmx.EvdoMX

public int SetUplinkWalshCodeLength(string selectorString, int value)

Remarks

This method sets the value of CdaUplinkWalshCodeLength attribute.The default value is 16. Valid values are 2, 4, 8, 16, and 32.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

valueint

Specifies the Walsh code length of the channel, subject to channel-specific analysis.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.