Returns the absolute and relative powers measured in the carriers. The relative powers are measured relative to the integrated power of the power reference carrier. Use "carrier(n)" as the selector string to read results from this method.

Syntax

Namespace: NationalInstruments.RFmx.EvdoMX

public int FetchCarrierMeasurement(string selectorString, double timeout, out double absolutePower, out double relativePower)

Parameters

NameTypeDescription
selectorStringstring

Specifies a selector string comprising of the result name, and carrier number. If you do not specify the result name, the default result instance is used.

timeoutdouble

Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete.

absolutePowerout double

Upon return, contains the absolute carrier power. This value is expressed in dBm.

relativePowerout double

Upon return, contains the relative carrier power. This value is expressed in dB.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.