Specifies whether the demodulator needs to search and synchronize the signal to a known reference sequence. The reference sequence is the symbol representation of a defined set of bits known to be present in the transmitted signal. If the synchronization is found in the demodulated signal, the measurement is performed from this point onward. If the synchronization is not found, the entire signal is used for the measurement.

You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is False.

Remarks

The following table lists the characteristics of this property.

Short Name DDemod Sync Enabled
Data type ci32.png
Permissions Read/Write
High-level VIs RFmxDemod DDemod Configure Synchronization
Resettable Yes
False 0

Does not search and synchronize the signal.

True 1

Searches and synchronizes the signal.