RFmx SpecAn Properties

Table of Contents

IM:Maximum Intermod Order Property

  • Updated2024-04-10
  • 1 minute(s) read

IM:Maximum Intermod Order Property

Short Name: IM Max Intermod Order

Property of RFmxSpecAn

Specifies the order up to which the RFmx driver measures odd order intermodulation products when you set the Auto Intermods Setup Enabled property to True. The lower and upper intermodulation products are measured for each order.

You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is 3.

3 (3)

The third order intermodulation products are measured.

5 (5)

The third and fifth order intermodulation products are measured.

7 (7)

The third, fifth, and seventh order intermodulation products are measured.

9 (9)

The third, fifth, seventh, and ninth order intermodulation products are measured.

Remarks

The following table lists the characteristics of this property.

Datatype ci32.gif
PermissionsRead/Write
High-level VIs N/A
ResettableYes

Log in to get a better experience