Measurement Interval
- Updated2025-10-08
- 1 minute(s) read
RFmx EV-DO determines the measurement interval used for modulation accuracy (ModAcc) measurements using the following values. You can configure the values independently or use the ModAcc Configure Synchronization Mode and Interval VI/function to configure them at the same time.
- Interval Start—Specifies the offset in slots relative to a
synchronization event. The synchronization event is configurable as the first
detected symbol, slot, or frame boundary within the acquired signal. Each
synchronization mode synchronizes to a chip offset relative to the frame start as an
integer multiple of the following sizes:
- Symbol synchronization—64 chips
- Slot synchronization—2048 chips
- Frame synchronization—32,768 chips
- Interval Duration—Specifies the length of the signal to be analyzed. This length is expressed in slots. Configure the interval duration using the Measurement Length (slots) property.
Note The sum of the interval start value and
the interval duration value must not be larger than 16 slots.