Cabling for High-Speed Data Movement
- Updated2025-12-19
- 3 minute(s) read
You must cable the hardware of each RPS system component together to enable high-speed data transfer between the VSTs in the instrument controller and the NICs of the data storage server.
Connecting the High-Speed Serial Cabling
Gather the following items to connect your RF multi-channel recording system for high-speed serial cabling.
| Data Streams | Component | Quantity |
|---|---|---|
| 1 | VST: PXIe-5842 | 1 |
| Stream Translation Module: PXIe-8290 | 1 | |
| zHD-to-zHD Cable: NI part number 788927-01/02 (1 m and 2 m lengths) | 2 | |
| 2 | VST: PXIe-5842 | 2 |
| Stream Translation Module: PXIe-8290 | 2 | |
| zHD-to-zHD Cable: NI part number 788927-01/02 (1 m and 2 m lengths) | 4 | |
| 4 | VST: PXIe-5842 | 4 |
| Stream Translation Module: PXIe-8290 | 4 | |
| zHD-to-zHD Cable: NI part number 788927-01/02 (1 m and 2 m lengths) | 8 |
Connect the Multi-Gigabit Transceiver (MGT) ports on VST(s) to the stream translation module(s) with the zHD-to-zHD cable.
You must connect each VST to a stream translation module with a zHD cable pair. The following table describes the set of valid connections between these instruments.
| High-Sped Serial Connection Label | Stream Translation Module: MGT Port | VST: MGT Port |
|---|---|---|
| HSS0 | 8290_00: MGT 0 | 5842_00: MGT 0 |
| 8290_00: MGT 1 | 5842_00: MGT 1 | |
| HSS1 | 8290_01: MGT 3 | 5842_01: MGT 0 |
| 8290_01: MGT 7 | 5842_01: MGT 1 |
Each stream translation module supports up to two simultaneous HSS connections (zHD pairs), and each HSS connection enables both a record and playback data stream simultaneously. However, each stream translation module supports only two simultaneous data streams. Therefore, only three configurations are possible.
| VST Connected to HSS0 | VST Connected to HSS1 |
|---|---|
| Generation and Acquisition | Not in use |
| Not in use | Generation and Acquisition |
| Generation or Acquisition | Generation or Acquisition |
Connecting the 100 GbE QSFP Cabling
Gather the following items to connect your RF multi-channel recording system for high-speed data transmission.
| Data Streams | Component | Quantity |
|---|---|---|
| 1 | Stream Translation Module: PXIe-8290 | 1 |
| Data Storage Server: Dell PowerEdge R7625 | 1 | |
| Dell Networking QSFP28-to-QSFP28 Cable: 617115-01 | Refer to the following table. | |
| 2 | Stream Translation Module: PXIe-8290 | 2 |
| Data Storage Server: Dell PowerEdge R7625 | 1 | |
| Dell Networking QSFP28-to-QSFP28 Cable: 617115-01 | Refer to the following table. | |
| 4 | Stream Translation Module: PXIe-8290 | 4 |
| Data Storage Server: Dell PowerEdge R7625 | 1 | |
| Dell Networking QSFP28-to-QSFP28 Cable: 617115-01 | Refer to the following table. |
Connect the Port 1 and/or Port 2 Multi-Gigabit Transceiver (MGT) terminals on the stream translation module(s) to the data storage server(s) with QSFP28-to-QSFP28 cabling.
Each QSFP cable supports a single data stream. The quantity of connections required depends on how the high-speed serial connections on the stream translation module are being utilized, as listed in the following table.
| Stream Translation Module HSS0 Utilization | Stream Translation Module HSS1 Utilization | QSFP Cable Quantity |
|---|---|---|
| Generation and Acquisition | Not in use | 2 |
| Not in use | Generation and Acquisition | 2 |
| Generation or Acquisition | Generation or Acquisition | 2 |
| Generation or Acquisition | Not in use | 1 |
| Not in use | Generation or Acquisition | 1 |
There is no fixed mapping between HSS connection and QSFP port a stream translation module. The path data takes between these physical connectors is defined in the STsc configuration files: STsc.ini and datapaths.ini.
There is also no constraint on which QSFP ports on a stream translation module connect to which QSFP ports on a data storage server. Each QSFP port on a stream translation module may be connected to the same or different data storage server(s). The connections between these components are defined by the RPS configuration files: RPS.ini and connections.ini.
Data can be routed from any ETH connection to or from any NVMe data storage array, with some constraints. These routes are called RPDSsc endpoints and defined in the RPDSsc endpoints configuration file: endpoints.conf.
Related Information
- STsc Core Configuration File
Modify the STsc core configuration file, STsc.ini, to define application settings for the Stream Translator System Component.
- STsc Datapaths Configuration File
Modify the STsc data paths configuration file, datapaths.ini, to define the STsc data paths between the HSS ports and ETH ports of each stream translation module managed by a given instance of STsc.
- Core Configuration File
Modify the RPS core configuration file, RPS.ini, to define user-configurable parameters for RPS.
- Connections Configuration File
Create a connections configuration file, such as connections.ini, to define the addresses of the gRPC servers for each modular system component instance used in your RPS system and the high-speed data connections between them.
- RPDSsc Endpoints Configuration File
Modify the RPDSsc endpoints configuration file, endpoints.conf, to define how data is routed between NIC ports and the file systems of the data storage server RAIDs.