PXI-2796 Overview
- Updated2023-02-18
- 2 minute(s) read
PXI-2796 Overview
PXI-2796 Pinout
| Signal | Description |
|---|---|
| CHxA | Bank A signal connection |
| CHxB | Bank B signal connection |
| COMx | Routing destination for channels on the corresponding bank |
PXI-2796 Hardware Diagram
This figure shows the hardware diagram of the module.
PXI-2796 Topology
This figure shows the topology of the module.
Module software name: 2796/Dual 6x1 Mux (NISWITCH_TOPOLOGY_2796_DUAL_6X1_MUX)
Dual 6x1 Multiplexer
Making a Connection
In this topology, you can connect channels by calling the niSwitch Connect Channels VI or the niSwitch_Connect function.
To connect the CHnx terminal to the COMx terminal, disconnect the previously connected terminal from the COMx.
For example, to connect ch1A to comA, call niSwitch_Connect (vi, "ch1A", "comA"). If you now want to connect ch2A to comA, first disconnect the existing connection. The sequence of calls for this task is as follows:
niSwitch_Disconnect (vi, "ch1A", "comA")
niSwitch_Connect (vi, "ch2A", "comA")
When scanning the module, a typical scan list entry could be ch1A->comA;. This entry routes the signal connected to CH1A to COMA.