PXI-2556 Overview
- Updated2023-02-18
- 2 minute(s) read
PXI-2556 Overview
PXI-2556 Pinout
Signal | Description |
---|---|
CHxA | Bank A signal connection |
CHxB | Bank B signal connection |
COMx | Routing destination for channels on the corresponding bank |
PXI-2556 Hardware Diagram
This figure shows the hardware diagram of the module.
PXI-2556 Topology
This figure describes the topology of the module.
Module software name: 2556/Dual 4x1 Mux (NISWITCH_TOPOLOGY_2556_DUAL_4X1_MUX)
Making a Connection
Call the niSwitch Connect Channels VI or the niSwitch_Connect function to connect channels in this topology. If applicable, you must call the niSwitch Disconnect Channels VI or the niSwitch_Disconnect function to disconnect an existing connection before you call the niSwitch Connect Channels VI or the niSwitch_Connect function.
The following sequence of tasks illustrates the VI/function calls necessary to make consecutive connections—one between CH 1A and COM A and the other between CH 2A and COM A:
- Call the niSwitch Connect Channels VI or the niSwitch_Connect function with parameters ch1A and comA.
- Call the niSwitch Disconnect Channels VI or the niSwitch_Disconnect function with parameters ch1A and comA.
- Call the niSwitch Connect Channels VI or the niSwitch_Connect function with parameters ch2A and comA.
When scanning the module, a typical scan list entry might be ch1A->comA;. This entry routes the signal connected to CH 1A to COM A.