Provides advanced properties related to signal path.

Derives from

Syntax

Namespace: NationalInstruments.ModularInstruments.NIRfsa

public class RfsaAdvancedSignalPath : RfsaSubObject

Remarks

For more information, refer to NI RF Vector Signal Analyzers Help.

Properties

NameDescription
AbsoluteDelay

Gets or sets the sub-sample clock delay, in seconds, to apply to the acquired signal. Use this property to reduce the trigger jitter when synchronizing multiple devices with NI-TClk. This property can also help maintain synchronization repeatability by writing the absolute delay value of a previous measurement to the current session. To set this property, the NI-RFSA device must be in the Configuration state.

Note

If this value is set, NI-TClk cannot do any sub-sample clock adjustment.

AvailablePaths

Returns a comma separated list of the configurable paths available for use based on your instrument configuration.

DownconverterLoopBandwidth

Gets or sets the loop bandwidth of the downconverter tuning phase-locked loops (PLL).

DownconverterPreselectorEnabled

Gets or sets whether the tunable preselector is enabled on the downconverter.

FrequencySettlingTime

Gets or sets the value used for LO frequency settling.

FrequencySettlingUnits

Gets or sets the delay duration units and interpretation for LO settling.

IFConditioningDownconversionEnabled

Gets or sets whether downconversion to 21.4 MHz is enabled for the IF conditioning module.

InputIsolationEnabled

Gets or sets whether input isolation is enabled.

InputPort

Gets or sets the connector(s) to acquire the signal.

LOFrequencyStepSize

Gets or sets the step size for tuning the local oscillator (LO) phase-locked loop (PLL).

LOInjectionSide

Gets or sets the LO injection side.

LOInPower

Gets the power level, in dBm, expected at the LO terminal when the LOSource property is set to LOIn.

LOOutPower

Gets or sets the power level, in dBm, of the signal at the LO OUT terminal when the LOExportEnabled property is set to true.

LOPllFractionalModeEnabled

Gets or sets whether to use fractional mode for the LO PLL.

LowFrequencyBypassEnabled

Gets or sets whether to use the low-frequency bypass path for the incoming RF signal.

NotchFilterEnabled

Gets or sets whether the notch filter is enabled on the RF conditioning module.

RFHighPassFiltering

Gets or sets the maximum corner frequency of the high pass filter in the RF signal path.

RFPreselectorFilter

Gets or sets the RF preselector filter to use.

SelectedPath

Gets or sets which path to configure to acquire a signal.