Adjusts the dynamics of the current driving the YIG main coil.

Note Setting this property to Fast allows the frequency to settle significantly faster for some frequency transitions at the expense of increased phase noise. This property is not supported if you are using an external LO.

Default Value: Normal

Supported Devices: PXIe-5603/5605/5606 (external digitizer mode), PXIe-5665/5667/5668

Remarks

The following table lists the characteristics of this property.

Short Name LO YIG Main Coil Drive
Data type ci32.png
Permissions Read/Write
High-level VIs N/A
Channel-based No
Resettable Yes
Normal 2400

Adjusts the YIG main coil on the LO for an underdamped response.

Fast 2401

Adjusts the YIG main coil on the LO for an overdamped response.