niUSRP Configure Number of Samples

Specifies whether the device operation is finite or continuous and the number of samples to acquire.

Inputs/Outputs

datatype_icon

session handle

Instrument session.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Default value: No error

datatype_icon

number of samples is finite

Boolean that specifies how many samples are acquired by the device.

True Device acquires a finite number of samples.
False Device acquires samples continuously.

Default value: False

datatype_icon

number of samples

Number of samples to acquire from the device.

This value is ignored if number of samples is finite is False.
datatype_icon

session handle out

Reference to your instrument session to be passed to the next node.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Hardware Support

This node supports the following hardware:

  • USRP-2900/2901
  • USRP-2920/2921/2922
  • USRP-2930/2932
  • USRP-2940/2942/2943/2944/2945
  • USRP-2950/2952/2953/2954/2955