Configures the TClks on all devices and prepares the Sync Pulse Sender for synchronization.

Inputs/Outputs
sessions
—
sessions specifies the array of session references that are being synchronized. Obtain session references from the instrument driver by using the <driver name> Get Session Reference VI, where <driver name> is the name of the instrument driver, for example, the niScope Get Session Reference VI.
minimum T clock period
—
minimum T clock period specifies the minimum TClk period, in seconds. The minimum period for a single chassis/PC is 200 ns. If the specified value is less than 200 ns, NI-TClk automatically coerces the minimum TClk period to 200 ns. For multichassis synchronization, adjust this value to account for the propagation delays through the various devices and cables. Valid values are 0.0 s to 0.050 s (50 ms), inclusive.
error in (no error)
—
error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.
sessions out
—
sessions out passes the array of session references to the next VI.
error out
—
error out contains error information. This output provides standard error out functionality. |