Set Time Reference Multimode Function
Sets the external time reference of a time-based timing and synchronization module. NI-Sync uses this time reference to update the value and frequency of the module's board time.
Timing nodes for NI-Sync devices.
Sets the external time reference of the device to 1588 ordinary clock.
Sets the external time reference of the device to 802.1AS clock.
Sets the time reference of the device to free running.
Sets the external time reference of the device to GPS.
Sets the external time reference of the device to IRIG-B AM or IRIG-B DC.
Set the external time reference of the device to PPS (pulse per second).