Route Scan Advanced Output
- Updated2023-05-15
- 3 minute(s) read
Route Scan Advanced Output
Routes the scan advanced output trigger from a trigger bus line (TTLx) to the front or rear connector.
Use this node when handshaking with a switch module that is not directly cabled to the controller. In this module's session, set the scan advanced output bus line to a trigger bus line. In the cabled module's session, use this node to route from the trigger bus line to the front or rear connector of the cabled module.
Inputs/Outputs

invert
Boolean input that reverses the input trigger signal from rising to falling and falling to rising.
| TRUE | Reverses the input trigger signal. |
| FALSE | Does not reverse the input trigger signal. |
Default value: FALSE (0)

session in
Control that identifies a particular NI-SWITCH session established with the niSwitch Initialize With Topology node, the niSwitch Initialize With Options node, or the niSwitch Initialize node.

error in
Error conditions that occur before this node runs.
The node responds to this input according to standard error behavior.
Default value: No error

scan advanced output connector
Destination of the Scan Advanced Output.

scan advanced output bus line
Trigger line that routes the scan advanced output trigger from the front or rear connector.
Default value: None

session out
Indicator that identifies a particular NI-SWITCH session established with the niSwitch Initialize With Topology node, the niSwitch Initialize With Options node, or the niSwitch Initialize node and used for all subsequent NI-SWITCH calls.

error out
Error information.
The node produces this output according to standard error behavior.
Programming Patterns
If this node is used to route scan advanced from a TTL line, specify the TTL line as the scan advanced output destination in the niSwitch Configure Scan Trigger node.