niSwitch Convert Thermistor Reading VI
- Updated2025-10-06
- 2 minute(s) read
Converts a thermistor voltage into temperature.

Inputs/Outputs
Type of Excitation
—
Type of Excitation distinguishes the two modes of operation of the VI.
Voltage
—
Voltage is the voltage read from a thermistor.
Voltage Reference
—
Voltage Reference (V^REF) is the reference you apply across a resistor of known value in series with your thermistor.
R1
—
R1 is the value of the resistor in series with your thermistor expressed in Ohms.
Excitation Current
—
Excitation Current (I^EX) is the current excitation applied to the thermistor.
Temperature Units (C)
—
Temperature Units are the units of temperature to be put out by the VI.
Temperature
—
Temperature is the return temperature value in the units specified in Temperature Units. |
Type of Excitation
—
Voltage
—
Temperature
—