Configure Start Trigger Input VI
- Updated2024-11-14
- 2 minute(s) read
Configures the trigger to start the S-parameter measurement. The measurement is complete when there is a rising edge on the assigned trigger. This configuration only supports the 2 couplers per port 1 VST with solid state switch setup. If the trigger is not configured or configured for an unsupported setup the measurement is performed immediately after initiated.

Inputs/Outputs
S-Par Reference In
—
Specifies the session reference handle of the S-parameter measurement session.
Start Trigger Input
—
Specifies the terminal on which the S-parameter session looks for a start trigger. The default value is None.
error in
—
Error conditions that occur before this node runs. This input provides standard error in functionality.
S-Par Reference Out
—
Returns the session reference handle of the S-parameter measurement session.
error out
—
Error information. This output provides standard error out functionality. |
S-Par Reference In
—
Start Trigger Input
—
error in
—
S-Par Reference Out
—
error out
—