Configure RFSG Attenuation (Constant) VI
- Updated2024-11-14
- 2 minute(s) read
Specifies a single value to compensate for the attenuation on the signal path from VST RF out to the ports connected to the DUT.

Inputs/Outputs
Path Selection
—
Specifies the path to apply the attenuation setting.
S-Par Reference In
—
Specifies the session reference handle of the S-parameter measurement session.
Tx Constant Attenuation (dB)
—
Specifies the constant attenuation value applied to the RFSG session. For example, if the attenuation is set to 1 dB and the Configure RFSG Power Level VI Power Level (dBm) input is set to 0 dBm, the actual power level at the VST RFout port is 1 dBm to compensate for the attenuation on the signal path.
error in
—
Error conditions that occur before this node runs. This input provides standard error in functionality.
S-Par Reference Out
—
Returns the session reference handle of the S-parameter measurement session.
error out
—
Error information. This output provides standard error out functionality. |
Path Selection
—
S-Par Reference In
—
Tx Constant Attenuation (dB)
—
error in
—
S-Par Reference Out
—
error out
—