Configures the frequency range used for S-parameter measurements.


icon

Inputs/Outputs

  • cdatavalref.png S-Par Reference In

    Specifies the session reference handle of the S-parameter measurement session.

  • cdbl.png Start Frequency (Hz)

    Specifies the beginning frequency of the stimulus to be applied to the DUT. The default value is 5 GHz.

  • cdbl.png Frequency Step (Hz)

    Specifies the frequency step size of the stimulus to be applied to the DUT. The default value is 50 MHz.

  • cdbl.png Stop Frequency (Hz)

    Specifies the ending frequency of the stimulus to be applied to the DUT. The default value is 5.5 GHz.

  • cerrcodeclst.png error in

    Error conditions that occur before this node runs. This input provides standard error in functionality.

  • idatavalref.png S-Par Reference Out

    Returns the session reference handle of the S-parameter measurement session.

  • ierrcodeclst.png error out

    Error information. This output provides standard error out functionality.