I-Q Arrays SGL
- Updated2023-02-17
- 3 minute(s) read
I-Q Arrays SGL
Writes an arbitrary waveform to the NI-RFSG device.
This node accepts the I and Q vectors of a complex baseband signal containing singles.
When streaming is enabled, you can call this node when the NI-RFSG device is in the Generation state.
Inputs/Outputs

error in
Error conditions that occur before this node runs.
The node responds to this input according to standard error behavior.
Default value: No error

I data
In-phase (I) component of the complex baseband signal.

Q data
Quadrature-phase (Q) component of the complex baseband signal.

name
Name used to store the waveform.

more data pending?
Boolean value that indicates whether the data block contains the end of the waveform.
| True | Allows the data to be appended to the waveform later. |
| False | This data block contains the end of the waveform. |
Splitting the waveform into multiple data blocks can reduce the memory requirements of the write operation. You can append data to a previously written waveform by using the saved waveform name.

session out
Reference to your instrument session passed to the next node.

error out
Error information.
The node produces this output according to standard error behavior.
Hardware Support
This node supports the following hardware:
- PXIe-5644/5645/5646
- PXIe-5673E
- PXIe-5820/5840