Configure Generation Mode
- Updated2023-02-17
- 2 minute(s) read
Configure Generation Mode
Configures the NI-RFSG device to generate a continuous sine tone (CW), apply I/Q (vector) modulation to the RF output signal, or generate arbitrary waveforms according to scripts.
The NI-RFSG device must be in the Configuration state before you call this node.
Inputs/Outputs

error in
Error conditions that occur before this node runs.
The node responds to this input according to standard error behavior.
Default value: No error

generation mode
Mode used to generate an RF output signal.
| CW | 0 | Configures the RF analog signal generator to generate a CW signal. |
| Arb Waveform | 1 |
Configures the RF analog signal generator to generate arbitrary waveforms. This mode is not supported for the PXI/PXIe-5650/5651/5652 , PXIe-5654/5654 with PXIe-5696. |
| Script | 2 |
Configures the RF analog signal generator to generate arbitrary waveforms as directed by scripts. This mode is not supported for the PXI/PXIe-5650/5651/5652 , PXIe-5654/5654 with PXIe-5696. Some script instructions are not supported for use with vector signal transceivers. |
Default value: CW

session out
Reference to your instrument session passed to the next node.

error out
Error information.
The node produces this output according to standard error behavior.
Hardware Support
This node supports the following hardware:
- PXIe-5644/5645/5646
- PXI/PXIe-5650/5651/5652, PXIe-5653/5654/5654 with PXIe-5696
- PXIe-5673E
- PXIe-5820/5840
Examples
Search within the programming environment to access the following installed examples:
- RFSG Getting Started Single Tone Generation (CW)
- RFSG Arbitrary Waveform Generation (Arb)
- RFSG Getting Started Script (Script)