Configures the acquisition time and trigger parameters for data acquisition using a digital edge trigger.

Syntax

Namespace: NationalInstruments.PowerSignalsDaq

public void ConfigureAcquisitionTime(TimeSpan totalAcquisitionTime, TimeSpan pretriggerTime, string triggerSource, DigitalEdgeTriggerEdge triggerEdge)

Remarks

Note

To ensure the desired acquisition time parameters are applied, you must call the ConfigureAcquisitionTime(TimeSpan, TimeSpan, string, DigitalEdgeTriggerEdge) method after creating all the required input channels with the CreateCurrentInputChannel or CreateVoltageInputChannel method.

Note

NI recommends using TimeSpan.FromTicks() when providing values for the totalAcquisitionTime  and pretriggerTime  parameters to avoid unintended data rounding. 1 tick = 100 ns, e.g. TimeSpan.FromTicks(10000) = 1 ms.

Parameters

NameTypeDescription
totalAcquisitionTimeTimeSpan

Specifies the total duration of the acquisition.

pretriggerTimeTimeSpan

Specifies the minimum duration of time for which data is acquired per channel before recognizing the Reference Trigger. The post-trigger time is equal to totalAcquisitionTime  minus pretriggerTime . The pretrigger samples per channel is calculated by multiplying the pretrigger time by the maximum Sample Clock rate supported by the session.

triggerSourcestring

Specifies the name of a channel or terminal where there is a digital signal to use as the source of the trigger.

triggerEdgeDigitalEdgeTriggerEdge

Specifies on which edge of the digital signal to start acquiring samples.

Exceptions

TypeDescription
PowerSignalsDaqException

Thrown when one of the following error conditions occurs: