Fetch PxdB (Trace) VI
- Updated2024-12-03
- 3 minute(s) read
Fetches the compression power at x dB (PxdB) in a trace format.

Inputs/Outputs
PAE Reference In
—
Specifies the session reference handle of the PAE measurement session.
PxdB Not Found Value
—
Specifies the value to be returned when the PxdB value is not found. The default value is 0.
error in
—
Error conditions that occur before this node runs. This input provides standard error in functionality.
PAE Reference Out
—
Returns the session reference handle of the PAE measurement session.
Power Output at PxdB
—
Returns the output power o fthe DUT when the DUT is in compression of PxdB over a frequency range.
Power Input at PxdB
—
Returns the input power to the DUT when the DUT is in compression of PxdB over a frequency range.
PxdB Not Found
—
Returns the input power when the DUT is in compression of PxdB over a frequency range.
error out
—
Error information. This output provides standard error out functionality. |
PAE Reference In
—
PxdB Not Found Value
—
error in
—
PAE Reference Out
—
Power Output at PxdB
—
Frequencies (Hz)
—
error out
—