Fetch Averaged Power VI
- Updated2024-12-03
- 3 minute(s) read
Fetches the averaged RF power and the averaged DC power of the measurement.

Inputs/Outputs
PAE Reference In
—
Specifies the session reference handle of the PAE measurement session.
error in
—
Error conditions that occur before this node runs. This input provides standard error in functionality.
PAE Reference Out
—
Returns the session reference handle of the PAE measurement session.
Averaged RF Power
—
Returns a 1D array of plots of RF power at DUT output port against RF power at DUT input port. Each plot in the array corresponds to one frequency in the frequency sweep.
Averaged DC Power
—
Averaged DC Power Returns a 1D array of plots of DC power against the RF power at the DUT input port. Each plot in the array corresponds to one frequency in the frequency sweep.
Frequencies
—
The frequency points the measurement was performed at. The index into this array corresponds to the index into the Averaged RF Power array and the Averaged DC Power array.
error out
—
Error information. This output provides standard error out functionality. |