Configure DCPower to RFSG Trigger (Manual Routing) VI
- Updated2024-12-03
- 3 minute(s) read
Configures the trigger that synchronizes the RF pulse to the DC pulse. The terminals on this VI are used for the DC Source Complete Event Out Terminal and the RFSG Pulse Trigger In Terminal. The Source Complete event is generated after both the configured delay and sourcing operation are complete. In CW mode the setting of the RFSG pulse trigger is ignored.

Inputs/Outputs
DCPower Source Complete Event Out Terminal
—
Specifies where to export the signal. The default value is an empty string. An empty string indicates this event is not exported.
—
Specifies where to export the signal. The default value is an empty string. An empty string means that an RFSG Pulse trigger is not used.
PAE Reference In
—
Specifies the session reference handle of the PAE measurement session.
DCPower Source Delay (s)
—
Specifies the time, in seconds, between the start of the DC pulse and the generation of the Source Complete event. The default value is 0.
RFSG Pulse Trigger Delay (s)
—
Specifies the time, in seconds, between when RFSG receives the pulse trigger and when it starts generating the pulse. The default value is 0.
error in
—
Error conditions that occur before this node runs. This input provides standard error in functionality.
PAE Reference Out
—
Returns the session reference handle of the PAE measurement session.
error out
—
Error information. This output provides standard error out functionality. |
DCPower Source Complete Event Out Terminal
—
—
PAE Reference In
—
DCPower Source Delay (s)
—
error in
—
PAE Reference Out
—
error out
—