When the DCPower mode is pulsed, this method uses dynamic routing to set the DCPower Source Complete event as the input to the RFSG Pulse Trigger using an available PXI backplane trigger line. When the DCPower mode is constant, this method does not export the DC Power Source Complete event or configure the RF Pulse trigger input. The Source Complete event is generated after both the configured delay and sourcing operation are complete. In CW mode the setting of the RFSG pulse trigger is ignored.


icon

Inputs/Outputs

  • cdatavalref.png PAE Reference In

    Specifies the session reference handle of the PAE measurement session.

  • cdbl.png DCPower Source Delay (s)

    Specifies the time, in seconds, between the start of the DC pulse and the generation of the Source Complete event. The default value is 0.

  • cdbl.png RFSG Pulse Trigger Delay (s)

    Specifies the time, in seconds, between when RFSG receives the pulse trigger and when it starts generating the pulse. The default value is 0.

  • cerrcodeclst.png error in

    Error conditions that occur before this node runs. This input provides standard error in functionality.

  • idatavalref.png PAE Reference Out

    Returns the session reference handle of the PAE measurement session.

  • ierrcodeclst.png error out

    Error information. This output provides standard error out functionality.