Configures DCPower to generate voltage pulses.


icon

Inputs/Outputs

  • cdatavalref.png PAE Reference In

    Specifies the session reference handle of the PAE measurement session.

  • cdbl.png Pulse Width (s)

    Specifies the pulse width, in us, of the voltage pulse The default value is 200.

  • cdbl.png Bias Voltage Level (V)

    Specifies the voltage level, in volts, during the low portion of the pulse for the DC Power. The default value is 0.

  • cdbl.png Bias Current Limit (A)

    Specifies the current limit, in mA, during the low portion of the pulse, for the DC Power. The default value is 100.

  • cerrcodeclst.png error in

    Error conditions that occur before this node runs. This input provides standard error in functionality.

  • idatavalref.png PAE Reference Out

    Returns the session reference handle of the PAE measurement session.

  • ierrcodeclst.png error out

    Error information. This output provides standard error out functionality.