Configure DCPower Measurement Interval VI
- Updated2024-12-03
- 2 minute(s) read
Specifies the duration of the voltage and current measurement.

Inputs/Outputs
PAE Reference In
—
Specifies the session reference handle of the PAE measurement session.
DCPower Measurement Interval (s)
—
Specifies the duration, in seconds, to measure voltage and current. The default value is .02 s. This value is limited by the capability of the instrument used. For example, for the PXIe-4130 the minimum is 0.00033 s (1 sample to average) and maximum is 0.170333 s (511 samples to average). For the PXIe-4139, refer to the PXI Source Measure Unit Manual for more details.
error in
—
Error conditions that occur before this node runs. This input provides standard error in functionality.
PAE Reference Out
—
Returns the session reference handle of the PAE measurement session.
error out
—
Error information. This output provides standard error out functionality. |
PAE Reference In
—
DCPower Measurement Interval (s)
—
error in
—
PAE Reference Out
—
error out
—