Close

Closes the specified session and frees reserved resources. If the session is running, it is first aborted.

To prevent generating unwanted signal glitches between initializing and closing sessions, no front panel terminals or channels are tristated by the Closenode. The terminals and channels are all left driving whatever voltage they would have been driving had you used the Abortnode.

Use the Resetnode before the Closenode if you want to tristate all terminals and channels before closing your session.

Inputs/Outputs

datatype_icon

session in

Instrument session obtained from the Initialize Acquisition Sessionnode, the Initialize Generation Sessionnode, or the Initialize External Calibrationnode.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Default value: No error

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior