Creates an onboard waveform from complex double-precision floating-point data for use in Arbitrary Waveform or Arbitrary Sequence output mode on devices with the OSP Enabled property set to TRUE and the Data Processing Mode property set to Complex. The Waveform Handle returned by the VI can be used later for setting the active waveform, changing the data in the waveform, building sequences of waveforms, or deleting the waveform when it is no longer needed.


icon

Inputs/Outputs

  • civrn.png Instrument Handle

    Instrument Handle identifies a particular instrument session.

    Instrument Handle is obtained from the niFgen Initialize VI, niFgen Initialize With Options VI, or the niFgen Initialize With Channels VI.

  • cstr.png Channel Name

    Channel Name specifies the channel that this VI uses.

  • c1dcdb.png Waveform Data Array

    Waveform Data Array specifies the array of data you want to load into the new waveform. The array must have at least as many elements as the value that you specify in the Waveform Size parameter.

    You must normalize the data points in the array to be between -1.00 and +1.00.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

    Default value: no error

  • iivrn.png Instrument Handle Out

    Instrument Handle Out passes a reference to your instrument session to the next VI.

  • ii32.png Waveform Handle

    Waveform Handle returns a handle that identifies the waveform.

  • ierrcodeclst.png error out