NI-FGEN C Function Reference

niFgen_ConfigureArbSequence

  • Updated2023-02-21
  • 2 minute(s) read

ViStatus niFgen_ConfigureArbSequence (ViSession vi, VViConstString channelName, ViInt32 sequenceHandle, ViReal64 gain, ViReal64 offset;

Purpose

Configures the signal generator attributes that affect arbitrary sequence generation. Sets the NIFGEN_ATTR_ARB_SEQUENCE_HANDLE, NIFGEN_ATTR_ARB_GAIN, and NIFGEN_ATTR_ARB_OFFSET attributes.

Notes  The signal generator must not be in the Generating state when you call this function.
You must call the niFgen_ConfigureOutputMode function to set the outputMode parameter to NIFGEN_VAL_OUTPUT_SEQ before calling this function.

Parameters

Input
Name Type Description
vi ViSession Identifies your instrument session. vi is obtained from the niFgen_init, niFgen_InitWithOptions, or niFgen_InitializeWithChannels functions and identifies a particular instrument session.
channelName ViConstString Specifies the channel name from which you want to configure an arbitrary sequence.

Default Value: "0"

sequenceHandle ViInt32 Specifies the handle of the arbitrary sequence that you want the signal generator to produce. NI-FGEN sets the NIFGEN_ATTR_ARB_SEQUENCE_HANDLE attribute to this value. You can create an arbitrary sequence using the niFgen_CreateArbSequence or niFgen_CreateAdvancedArbSequence function. These functions return a handle that you use to identify the sequence.

Default Value: None

gain ViReal64 Specifies the factor by which the signal generator scales the arbitrary waveforms in the sequence. When you create an arbitrary waveform, you must first normalize the data points to a range of –1.00 to +1.00. You can use this parameter to scale the waveform to other ranges. The gain is applied before the offset is added.

For example, to configure the output signal to range from –2.00 to +2.00 V, set gain to 2.00.

Units: unitless

Default Value: None

offset ViReal64 Specifies the value the signal generator adds to the arbitrary waveform data. When you create arbitrary waveforms, you must first normalize the data points to a range of –1.00 to +1.00 V. You can use this parameter to shift the range of the arbitrary waveform. NI-FGEN sets the NIFGEN_ATTR_ARB_OFFSET attribute to this value.

For example, to configure the output signal to range from 0.00 to 2.00 V instead of –1.00 to 1.00 V, set the offset to 1.00.

Units: volts

Default Value: None

Return Value

Name Type Description
status ViStatus Returns the status code of this operation. The status code either indicates success or describes an error or warning condition. You can examine the status code from each call to an NI-FGEN function to determine if an error occurred. To obtain a text description of the status code, call the niFgen_error_message function. To obtain additional information about the error condition, call the niFgen_GetError function. To clear the error information from NI-FGEN, call the niFgen_ClearError function.

The general meaning of the status code is as follows:

Value Meaning
0 Success
Positive Values Warnings
Negative Values Errors