Contains properties and methods to configure and control the start trigger for software triggering.

Derives from

Syntax

Namespace: NationalInstruments.ModularInstruments.NIDigital

public class DigitalSoftwareStartTrigger : DigitalSubObject

Remarks

The digital pattern instrument waits for this trigger after you call Initiate or you burst a pattern, and does not burst a pattern until it receives this trigger. Use the Send method to send the software trigger to the digital pattern instrument.
Note

Example applications are located in the <Public Documents>\National Instruments\NI-Digital\Examples\DotNET 4.x directory or in the Start menu at National Instruments » NI Digital Pattern Examples.

For more information on triggers, refer to the Triggers and Events and Supported Triggers and Events topics in the Digital Pattern Help.

Thread Safety

All members of this type are safe for multithreaded operations.

Methods

NameDescription
Configure()

Configures the TriggerType for Software triggering.

Send()

Sends the software start trigger to a digital pattern instrument, forcing the start trigger to assert, regardless of how the start trigger is configured.