Fetch History RAM Scan Cycle Numbers

Returns the scan cycle numbers acquired for the specified cycles.

1378

Inputs/Outputs

datatype_icon

session in

Instrument session obtained from the niDigital Initialize with Optionsnode.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Default value: No error

datatype_icon

site

Site specified as a string in the form of siteN, where N is the site number. The node returns an error if more than one site is specified.

datatype_icon

samples to read

Number of samples to fetch.

A value of -1 specifies to fetch all available samples.
datatype_icon

position

The sample index from which to start fetching pattern information.

datatype_icon

session out

Handle that identifies the session in all subsequent NI-Digital node calls.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

datatype_icon

scan cycle numbers

Returns the acquired scan cycle numbers. Scan cycle numbers start at 0 from the first cycle of the scan vector. Scan cycle numbers are -1 for cycles that do not have a scan opcode.