Disable Sites
- Updated2023-02-17
- 3 minute(s) read
Disable Sites
Disables specified sites.
Disabled sites are not included in pattern bursts initiated by the niDigital Initiate node or the niDigital Burst Pattern node, even if the site is specified in the list of pattern burst sites in niDigital Configure Pattern Burst Sites node or in the site list input of the niDigital Burst Pattern node.
Additionally, if you specify a list of pin or pin group names in a channel list parameter in any NI-Digital node, digital pattern instrument channels mapped to disabled sites are not affected by the node. The nodes that return per-pin data, such as the niDigital PPMU Measure node, do not return data for channels mapped to disabled sites.
The digital pattern instrument channels mapped to the sites specified are left in their current state.
NI TestStand Semiconductor Module requires all sites to always be enabled, and manages the set of active sites without disabling the sites in the digital instrument session. Do not use this function with the Semiconductor Module.
Inputs/Outputs

session in
Instrument session obtained from the niDigital Initialize with Optionsnode.

site list
Comma-delimited list of strings in the form of siteN, where N is the site number. If you enter an empty string, the node enables all sites.

error in
Error conditions that occur before this node runs.
The node responds to this input according to standard error behavior.
Default value: No error

session out
Handle that identifies the session in all subsequent NI-Digital node calls.

error out
Error information.
The node produces this output according to standard error behavior.
Compatibility with NI TestStand Semiconductor Module
NI TestStand Semiconductor Module requires all sites to always be enabled, and manages the set of active sites without disabling the sites in the digital instrument session. Do not use this node with the Semiconductor Module.