Configure Pattern Burst Sites
- Updated2023-02-17
- 2 minute(s) read
Configure Pattern Burst Sites
Configures which sites burst the pattern on the next call to the niDigital Initiate node.
The pattern burst sites can also be modified through the site list parameter in the niDigital Burst Pattern node.
If a site has been disabled through the niDigital Disable Sites node, the site does not burst a pattern even if included in the pattern burst sites.
Inputs/Outputs

session in
Instrument session obtained from the niDigital Initialize with Optionsnode.

site list
A comma-delimited list of strings in the form of siteN, where N is the site number. If you specify an empty string, the function returns pass or fail results for all sites.
If the string is empty, all sites are configured for pattern bursting.

error in
Error conditions that occur before this node runs.
The node responds to this input according to standard error behavior.
Default value: No error

session out
Handle that identifies the session in all subsequent NI-Digital node calls.

error out
Error information.
The node produces this output according to standard error behavior.