Configures the conditional jump trigger instance to trigger on an incoming digital edge and routes the specified signal source to the instrument.
Inputs/Outputs

session in
Instrument session obtained from the niDigital Initialize with Optionsnode.

trigger ID
Specifies which instance of the conditional jump trigger you want to override.
| conditionalJumpTrigger0 |
Configures the conditional jump trigger instance you specify. |
| conditionalJumpTrigger1 |
Configures the conditional jump trigger instance you specify. |
| conditionalJumpTrigger2 |
Configures the conditional jump trigger instance you specify. |
| conditionalJumpTrigger3 |
Configures the conditional jump trigger instance you specify. |

source
The string identifier for a supported trigger source terminal to route into the instrument for the conditional jump trigger instance. The PXIe-6570/6571 supports triggering through the PXI trigger bus.

edge
Specifies the polarity of the incoming trigger signal that will assert this conditional jump trigger instance.
| Rising edge |
Specifies the signal transition from low level to high level. |
| Falling edge |
Specifies the signal transition from high level to low level. |
Default value: Rising edge

error in
Error conditions that occur before this node runs.
The node responds to this input according to standard error behavior.
Default value: No error

session out
Handle that identifies the session in all subsequent NI-Digital node calls.

error out
Error information.
The node produces this output according to standard error behavior.