Specifies the current limit low, in amperes, that the output cannot exceed when generating the desired voltage on the specified channel(s) during the on phase of a pulse. This property is applicable only if the Function property is set to PulseVoltage and the DCPowerComplianceLimitSymmetry property is set to Asymmetric. A channel must be enabled for the specified current limit low to take effect. Refer to the Enabled property for more information about enabling the channel.

Syntax

Namespace: NationalInstruments.ModularInstruments.NIDCPower

public double CurrentLimitLow { get; set; }

Remarks

The valid values for this property are defined by the values you specify for the CurrentLimitRange property.

Note

NI-DCPower uses the terms "source" and "output". However, while sinking with electronic loads and SMUs these correspond to "sinking" and "input", respectively.