Contains properties used to configure the constant power custom transient response of source unit channel.

Derives from

Syntax

Namespace: NationalInstruments.ModularInstruments.NIDCPower

public class DCPowerOutputSourceCustomTransientResponseConstantPower : DCPowerSubObject

Remarks

For more information, refer to NI DC Power Supplies and SMUs Help.

Properties

NameDescription
CompensationFrequency

Specifies the frequency at which a pole-zero pair is added to the system when the Function property is set to ConstantPower and the output current is below the current limit.

GainBandwidth

Specifies the frequency at which the unloaded loop gain extrapolates to 0 dB in the absence of additional poles and zeroes when the Function property is set to ConstantPower and the output current is below the current limit.

PoleZeroRatio

Specifies the ratio of the pole frequency to the zero frequency when the Function property is set to ConstantPower and the output current is below the current limit.