Gets or sets the time, in seconds, when the device generates the SourceCompleteEvent.

Syntax

Namespace: NationalInstruments.ModularInstruments.NIDCPower

public NationalInstruments.PrecisionTimeSpan SourceDelay { get; set; }

Remarks

Valid Values:

For the PXIe-4051, 0 to 39 seconds.

For the PXIe-4147, 0 to 26.5 seconds.

For the PXIe-4151, 0 to 42 seconds.

For the PXIe-4162/4163 and PXIe-4190, 0 to 23 seconds.

For all other supported instruments, 0 to 167 seconds.

The default value is 0.01667.

Determines the time, in seconds, when the device generates the SourceCompleteEvent, potentially starting a measurement if the DCPowerMeasurementWhen property is set to AutomaticallyAfterSourceComplete. Refer to the Single Point Source Mode, and Sequence Source Mode topics in the NI DC Power Supplies and SMUs Help for more information.
Note

The NI PXI-4110 and NI PXI-4130 do not support this property.

Note

NI-DCPower uses the terms "source" and "output". However, while sinking with electronic loads and SMUs these correspond to "sinking" and "input", respectively.