Gets or sets whether a sequence should repeat indefinitely.

Syntax

Namespace: NationalInstruments.ModularInstruments.NIDCPower

public bool IsSequenceLoopCountFinite { get; set; }

Remarks

Refer to the Sequence Source Mode topic in the NI DC Power Supplies and SMUs Help for more information about the sequence loop count.
Note

This property is not supported by all instruments. Refer to the Supported Properties by Device topic in the NI DC Power Supplies and SMUs Help for information about supported instruments.

Note

To use the per-channel version of this property, you must first initialize the session with the NIDCPower(string, bool, string) constructor. If the session was initialized with a deprecated constructor, use the per-session version of this property instead or include all channels.

The default value is true. If this property is set to false, this property is ignored.

Exceptions

TypeDescription
System.ObjectDisposedException

The property was accessed after the associated NIDCPower object was disposed.

Ivi.Driver.OperationNotSupportedException

The property was accessed to unsupported hardware.

Ivi.Driver.SelectorNameException

The property was accessed with an unknown channel name.

Ivi.Driver.IviCDriverException

The underlying NI-DCPower driver returned an error.