Gets or sets a value indicating whether to take continuous measurements.

Syntax

Namespace: NationalInstruments.ModularInstruments.NIDCPower

public bool IsRecordLengthFinite { get; set; }

Remarks

Call Abort to stop continuous measurements. When this property is set to false and Mode is set to SinglePoint, MeasureWhen must be set to AutomaticallyAfterSourceComplete or OnMeasureTrigger. When this property is set to false and Mode is set to Sequence, MeasureWhen must be set to OnMeasureTrigger.
Note

This property is not supported by all instruments. Refer to the Supported Properties by Device topic in the NI DC Power Supplies and SMUs Help for information about supported instruments.

Note

To use the per-channel version of this property, you must first initialize the session with the NIDCPower(string, bool, string) constructor. If the session was initialized with a deprecated constructor, use the per-session version of this property instead or include all channels.

true, if continuous measurements are allowed; otherwise, false.

Exceptions

TypeDescription
System.ObjectDisposedException

The property was accessed after the associated NIDCPower object was disposed.

Ivi.Driver.OperationNotSupportedException

The property was accessed to unsupported hardware.

Ivi.Driver.SelectorNameException

The property was accessed with an unknown channel name.

Ivi.Driver.IviCDriverException

The underlying NI-DCPower driver returned an error.