| Name | Description |
|---|---|
| NIDCPOWER_ATTR_OUTPUT_CONNECTED | Specifies whether the output relay is connected (closed) or disconnected (open). The NIDCPOWER_ATTR_OUTPUT_ENABLED attribute does not change based on this attribute; they are independent of each other. |
| NIDCPOWER_ATTR_OUTPUT_ENABLED | Specifies whether the output is enabled (VI_TRUE) or disabled (VI_FALSE). |
| NIDCPOWER_ATTR_OUTPUT_FUNCTION | Configures the function to generate on the specified channel(s). |
| NIDCPOWER_ATTR_OUTPUT_RESISTANCE | Specifies the output resistance that the device attempts to generate for the specified channel(s). |
| NIDCPOWER_ATTR_SOURCE_MODE | Specifies whether to run a single output point or a sequence. Refer to the Single Point Source Mode and Sequence Source Mode topics in the NI DC Power Supplies and SMUs Help for more information about source modes. |
| NIDCPOWER_ATTR_TRANSIENT_RESPONSE | Specifies the transient response. |