AIChannelCollection.CreateAccelerometerChannel Method (String, String, AITerminalConfiguration, Double, Double, Double, AIAccelerometerSensitivityUnits, AIExcitationSource, Double, String)
- Updated2023-02-21
- 3 minute(s) read
Namespace: NationalInstruments.DAQmx
Assembly: NationalInstruments.DAQmx (in NationalInstruments.DAQmx.dll) Version: 20.7.40.49302
Syntax
public AIChannel CreateAccelerometerChannel( string physicalChannelName, string nameToAssignChannel, AITerminalConfiguration configuration, double minimumValue, double maximumValue, double sensitivity, AIAccelerometerSensitivityUnits sensitivityUnits, AIExcitationSource currentExcitationSource, double currentExcitationValue, string customScaleName )
Public Function CreateAccelerometerChannel ( physicalChannelName As String, nameToAssignChannel As String, configuration As AITerminalConfiguration, minimumValue As Double, maximumValue As Double, sensitivity As Double, sensitivityUnits As AIAccelerometerSensitivityUnits, currentExcitationSource As AIExcitationSource, currentExcitationValue As Double, customScaleName As String ) As AIChannel
Parameters
- physicalChannelName
- Type: SystemString
The names of one or more physical channels to use to create one or more local virtual channels. - nameToAssignChannel
- Type: SystemString
One or more names to assign to the created local virtual channels. To use the physical channel name as the local virtual channel name, set this value to Empty. - configuration
- Type: NationalInstruments.DAQmxAITerminalConfiguration
The input terminal configuration. To use the default terminal configuration for the physical channel(s) being used, pass a value of -1 casted to an AITerminalConfiguration. - minimumValue
- Type: SystemDouble
The minimum value expected from the measurement, in units. - maximumValue
- Type: SystemDouble
The maximum value expected from the measurement, in units. - sensitivity
- Type: SystemDouble
The sensitivity of the sensor. This value is in the units you specify with sensitivityUnits. Refer to sensor documentation to determine this value. - sensitivityUnits
- Type: NationalInstruments.DAQmxAIAccelerometerSensitivityUnits
The units of sensitivity. - currentExcitationSource
- Type: NationalInstruments.DAQmxAIExcitationSource
The source of excitation. - currentExcitationValue
- Type: SystemDouble
The amount of excitation in amps that the sensor requires. - customScaleName
- Type: SystemString
The name of the custom scale to apply to the local virtual channel.
Return Value
Type: AIChannelThe newly created AIChannel.
Exceptions
| Exception | Condition |
|---|---|
| DaqException | The NI-DAQmx driver returned an error. |
Remarks
This method creates a local virtual channel for every physical channel name you specify. If you create multiple local virtual channels with one call to this method, you can specify a comma-delimited list of names for nameToAssignChannel. If you provide fewer local virtual channel names in nameToAssignChannel than you create, NI-DAQmx automatically assigns names to the local virtual channels.
If you do not provide a value for nameToAssignChannel, NI-DAQmx uses the physicalChannelName as the local virtual channel name. If you use nameToAssignChannel to create a name for the local virtual channel, you must use this name in other properties and methods.
The NI-DAQmx driver does not determine if the requested settings are possible until the task is verified. CreateAccelerometerChannel(String, String, AITerminalConfiguration, Double, Double, Double, AIAccelerometerSensitivityUnits, AIExcitationSource, Double, String) does not throw an exception for parameter values that are not compatible with your hardware or other settings in your task. To determine if all of the settings for a Task are valid, you must verify the task by starting the task, either with Start or by reading from or writing to the task, or by calling Control(TaskAction) with Verify.