Creates channel(s) to generate digital pulses that frequency and duty cycle define. The pulses appear on the default output terminal of the counter unless you select a different output terminal.


icon

Inputs/Outputs

  • cdbl.png duty cycle

    duty cycle is the width of the pulse divided by the pulse period. NI-DAQmx uses this ratio combined with frequency to determine pulse width and the interval between pulses.

  • cdbl.png frequency

    frequency specifies at what frequency to generate pulses.

  • cgenclassrntag.png task in

    task in specifies the task to which to add the virtual channels this VI creates. If you do not specify a task, NI-DAQmx creates a task for you and adds the virtual channels this VI creates to that task.

  • cdaqmxscale.png counter

    counter specifies the names of the counters to use to create the virtual channels. The DAQmx physical channel constant lists all physical channels, including counters, for devices installed in the system.

    You also can wire a string that contains a list or range of counters to this input. If you have an array of counters, use the DAQmx Flatten Channel String VI to convert the array to a list.

  • cstr.png name to assign

    name to assign specifies a name to assign to the virtual channel this VI creates. If you do not wire a value to this input, NI-DAQmx uses the physical channel name as the virtual channel name.

    If you use this input to provide your own names for the virtual channels, you must use the names when you refer to these channels in other NI-DAQmx VIs and Property Nodes, such as the source input of the DAQmx Trigger VI.

    If you create multiple virtual channels with one DAQmx Create Virtual Channel VI, you can specify a comma-separated list of names to assign to the virtual channels. If you provide fewer names than the number of virtual channels you create, NI-DAQmx automatically assigns names to the virtual channels.

  • ci32.png units

    units specifies the units in which to define pulse frequency.

    Hz (10373)

    Hertz.

  • cerrcodeclst.png error in

    error in describes error conditions that occur before this VI or function runs.

    The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.

  • ci32.png idle state

    idle state specifies the resting state of the output terminal.

    High (10192)

    Terminal is at a high state at rest.

    Low (10214)

    Terminal is at a low state at rest.

  • cdbl.png initial delay

    initial delay is the amount of time in seconds to wait before generating the first pulse.

  • igenclassrntag.png task out

    task out is a reference to the task after this VI runs. The task contains any newly created virtual channels. If you did not wire a value to task in, NI-DAQmx automatically creates the task this output refers to.

  • ierrcodeclst.png error out

    error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces.

    Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.