DAQmx Set Power Up States (Analog) VI
- Updated2025-07-28
- 4 minute(s) read
(Deprecated) Updates power up states for analog physical channels.

Inputs/Outputs
device in
—
device in is the name as configured in MAX of the device to which this operation applies. A DAQmx device name constant lists all devices installed in the system.
voltage power up states
—
voltage power up states contains the physical channels and power up states to set. Each element of the array contains a physical channel and the power up state to set for that physical channel. You can set voltage power up states only for physical channels that support voltage output.
current power up states
—
current power up states contains the physical channels and power up states to set. Each element of the array contains a physical channel and the power up state to set for that physical channel. You can set current power up states only for physical channels that support current output.
error in
—
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
device out
—
device out is the name of the device the operation applied to.
error out
—
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error. |
device in
—
voltage power up states
—
value
—
error in
—
device out
—
error out
—