Start:More:Retrigger Window
- Updated2025-07-28
- 1 minute(s) read
Specifies the period of time in seconds after each trigger during which the device may trigger. Once the window has expired, the device stops detecting triggers, and the task will finish after the device finishes acquiring post-trigger samples that it already started. Ensure the period of time specified covers the entire time span desired for retrigger detection to avoid missed triggers. Specifying a Retrigger Window of -1 causes the window to be infinite.
Remarks
The following table lists the characteristics of this property.
| Short Name | Start.RetriggerWin |
| Data type | ![]() |
| Permissions | Read/Write |
| Resettable | True |
| Settable While Task Is Running | device-specific |
| Available in Run-Time Engine | True |