Reference:Analog Window:Trigger When
- Updated2025-07-28
- 1 minute(s) read
Specifies whether the Reference Trigger occurs when the source signal enters the window or when it leaves the window. Use Ref.AnlgWin.Btm and Ref.AnlgWin.Top to specify the window.
Remarks
The following table lists the characteristics of this property.
| Short Name | Ref.AnlgWin.TrigWhen |
| Data type | ![]() |
| Permissions | Read/Write |
| Resettable | True |
| Settable While Task Is Running | device-specific |
| Available in Run-Time Engine | True |
| Entering Window | 10163 | Trigger when the signal enters the window. |
| Leaving Window | 10208 | Trigger when the signal leaves the window. |